Page 247
... resistive construction , " " three - hour fire - resistive Construc- construction , " " two - hour fire - resistive construction " and " one- tion hour fire - resistive construction , " for fire - resistive purposes and Defined ...
... resistive construction , " " three - hour fire - resistive Construc- construction , " " two - hour fire - resistive construction " and " one- tion hour fire - resistive construction , " for fire - resistive purposes and Defined ...
Page 254
... resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of reinforced concrete , gypsum or solid ma ...
... resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of reinforced concrete , gypsum or solid ma ...
Page 258
... Resistive Shutters . One - hour fire - resistive shutters shall be constructed as specified for any one of the types of fire- resistive doors specified in part ( a ) of this Section . ( c ) One - Hour Fire - Resistive Windows . One ...
... Resistive Shutters . One - hour fire - resistive shutters shall be constructed as specified for any one of the types of fire- resistive doors specified in part ( a ) of this Section . ( c ) One - Hour Fire - Resistive Windows . One ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood