Page 65
... rooms when determin- ing room capacity . ( b ) Special Provisions . Rooms having a seating capacity of more than 100 and rooms used for kindergarten , first or second grade pupils shall not be located above the first story above grade ...
... rooms when determin- ing room capacity . ( b ) Special Provisions . Rooms having a seating capacity of more than 100 and rooms used for kindergarten , first or second grade pupils shall not be located above the first story above grade ...
Page 66
... rooms , auditoriums , and similar rooms wherein seats are either fixed or movable and the capa- city unit therefor shall be seven square feet ( 7 sq . ft . ) . Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit ...
... rooms , auditoriums , and similar rooms wherein seats are either fixed or movable and the capa- city unit therefor shall be seven square feet ( 7 sq . ft . ) . Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit ...
Page 109
... Rooms ... Hotels - Guest Rooms and Private Corridors . 40 40 Libraries - Reading Rooms Stack Rooms Loft Building Manufacturing - - Light .. 60 .125 ..100 75 Heavy ..125 Marquees 60 Offices 50 Printing Plants - Press Rooms ..... .150 ...
... Rooms ... Hotels - Guest Rooms and Private Corridors . 40 40 Libraries - Reading Rooms Stack Rooms Loft Building Manufacturing - - Light .. 60 .125 ..100 75 Heavy ..125 Marquees 60 Offices 50 Printing Plants - Press Rooms ..... .150 ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood