... seats are not provided the exits shall be propor- tioned on the seating capacity as defined in Section 401 and shall be evenly distributed and so arranged that the distance between adjacent exits shall not exceed one hundred feet ( 100 ...
... seats are not provided the exits shall be propor- tioned on the seating capacity as defined in Section 401 and shall be evenly distributed and so arranged that the distance between adjacent exits shall not exceed one hundred feet ( 100 ...
Page 59
... seats between any seat and an aisle . Aisles in balconies and galleries shall have the same mini- mum width as for aisles on the first floor and shall have the same ratio of increase in width with the exception that the increase shall ...
... seats between any seat and an aisle . Aisles in balconies and galleries shall have the same mini- mum width as for aisles on the first floor and shall have the same ratio of increase in width with the exception that the increase shall ...
Page 64
... seats between any seat and an aisle . 4. SEATS . Where seats are not marked or spaced off , a distance of eighteen inches ( 18 " ) along any bench or platform shall constitute one seat in computing the required aisles , stairs and exits .
... seats between any seat and an aisle . 4. SEATS . Where seats are not marked or spaced off , a distance of eighteen inches ( 18 " ) along any bench or platform shall constitute one seat in computing the required aisles , stairs and exits .
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood