... served on any persons engaged in the doing or causing such work to be done , and any such persons shall forthwith stop such work until authorized by the Building In- spector to recommence and proceed with the work . Whenever any ...
... served on any persons engaged in the doing or causing such work to be done , and any such persons shall forthwith stop such work until authorized by the Building In- spector to recommence and proceed with the work . Whenever any ...
Page 231
... serving floors above the first floor shall have a net area of not less than two - thirds that required to serve the first floor . Registers shall be located in or near the wall of the room nearest the furnace . No register shall be ...
... serving floors above the first floor shall have a net area of not less than two - thirds that required to serve the first floor . Registers shall be located in or near the wall of the room nearest the furnace . No register shall be ...
Page 232
... served by such warm air pipe divided by 40. Sizes of branch runs shall be determined in the same manner on the basis of the room or rooms served . Branches from trunk lines shall be taken off in a generally horizontal plane at an angle ...
... served by such warm air pipe divided by 40. Sizes of branch runs shall be determined in the same manner on the basis of the room or rooms served . Branches from trunk lines shall be taken off in a generally horizontal plane at an angle ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood