Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 15
Page 104
... sheathing not less than one and one - half inches ( 12 " ) thick or may be of laminated construction not less than four inches ( 4 " ) nominal in thickness with the ... Sheathing . Sheathing where required for exterior 104 Sections 2204-2205.
... sheathing not less than one and one - half inches ( 12 " ) thick or may be of laminated construction not less than four inches ( 4 " ) nominal in thickness with the ... Sheathing . Sheathing where required for exterior 104 Sections 2204-2205.
Page 105
Pacific Coast Building Officials Conference. ( b ) Sheathing . Sheathing where required for exterior walls shall be applied solidly over the wall surface and shall be one or more of the following materials : Wood not less than five ...
Pacific Coast Building Officials Conference. ( b ) Sheathing . Sheathing where required for exterior walls shall be applied solidly over the wall surface and shall be one or more of the following materials : Wood not less than five ...
Page 141
... sheathing and the sub - flooring shall be fastened to the studs , rafters or joists with nails which shall be in length at least two and one - half times the nominal thick- ness of the sheathing or subflooring . The nailing shall have ...
... sheathing and the sub - flooring shall be fastened to the studs , rafters or joists with nails which shall be in length at least two and one - half times the nominal thick- ness of the sheathing or subflooring . The nailing shall have ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood