Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 17
Page 57
... slope of not more than one in 10 . The foyer if not abutting directly upon a public street shall communicate therewith by a straight and unobstructed corridor or passageway equal in width to that required for the main en- trance which ...
... slope of not more than one in 10 . The foyer if not abutting directly upon a public street shall communicate therewith by a straight and unobstructed corridor or passageway equal in width to that required for the main en- trance which ...
Page 93
... slope along the length of any side of such building but in no case shall such height exceed eighty - five feet ( 85 ... slopes more than 20 degrees from the horizontal back from the exterior wall of such building . Inner court walls ...
... slope along the length of any side of such building but in no case shall such height exceed eighty - five feet ( 85 ... slopes more than 20 degrees from the horizontal back from the exterior wall of such building . Inner court walls ...
Page 218
... slope not greater than one foot ( 1 ' ) in eight feet ( 8 ' ) may be substituted . Ramps shall comply with all the requirements for stairways as to construction , width , enclosures , landing , lighting and ven- tilation . Ramps shall ...
... slope not greater than one foot ( 1 ' ) in eight feet ( 8 ' ) may be substituted . Ramps shall comply with all the requirements for stairways as to construction , width , enclosures , landing , lighting and ven- tilation . Ramps shall ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood