Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 68
Page 53
... space , yard , or street , and their areas shall not exceed the limits set forth in Table No. 5 - C ex- cept as provided in Section 506 , nor the limits specified in Chapter 16 . Buildings over one story in height shall adjoin a public ...
... space , yard , or street , and their areas shall not exceed the limits set forth in Table No. 5 - C ex- cept as provided in Section 506 , nor the limits specified in Chapter 16 . Buildings over one story in height shall adjoin a public ...
Page 65
... space under the first floor of two- story Type IV and V buildings , the construction up to and in- cluding the first floor shall be of Type I construction , and the first floor shall be unpierced for human access . Balconies and ...
... space under the first floor of two- story Type IV and V buildings , the construction up to and in- cluding the first floor shall be of Type I construction , and the first floor shall be unpierced for human access . Balconies and ...
Page 83
... space shall be limited to six hundred and fifty square Deviations feet ( 650 sq . ft . ) of floor area unless such storage space is separated from other portions of the building as required for public garages . General Restrictions in ...
... space shall be limited to six hundred and fifty square Deviations feet ( 650 sq . ft . ) of floor area unless such storage space is separated from other portions of the building as required for public garages . General Restrictions in ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood