Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 42
Page 64
... spaced off , a distance of eighteen inches ( 18 " ) along any bench or platform shall constitute one seat in computing the required aisles , stairs and exits . Seats shall be spaced not less than twenty - six inches ( 26 ′′ ) back to ...
... spaced off , a distance of eighteen inches ( 18 " ) along any bench or platform shall constitute one seat in computing the required aisles , stairs and exits . Seats shall be spaced not less than twenty - six inches ( 26 ′′ ) back to ...
Page 104
... spaced not more than sixteen inches ( 16 " ) on centers , or such walls may be constructed of not less than four inch by four inch ( 4 " x4 " ) posts spaced not more than five feet ( 5 ′ ) on centers or of larger members designed as ...
... spaced not more than sixteen inches ( 16 " ) on centers , or such walls may be constructed of not less than four inch by four inch ( 4 " x4 " ) posts spaced not more than five feet ( 5 ′ ) on centers or of larger members designed as ...
Page 140
... spaced more than sixteen inches ( 16 " ) center , except that in lieu of this requirement the studs and plates may be de- signed as a system of columns and beams , provided structural grade material is used . ( e ) Base Plates . Stud ...
... spaced more than sixteen inches ( 16 " ) center , except that in lieu of this requirement the studs and plates may be de- signed as a system of columns and beams , provided structural grade material is used . ( e ) Base Plates . Stud ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood