Page 55
Where public space, streets, or yards, more than twenty feet (20') in width, extend
on all sides of one and two-story buildings and adjoin the entire perimeter, the
areas specified in Section 505 may be increased at a rate of five per cent for each
...
Where public space, streets, or yards, more than twenty feet (20') in width, extend
on all sides of one and two-story buildings and adjoin the entire perimeter, the
areas specified in Section 505 may be increased at a rate of five per cent for each
...
Page 104
Buildings two stories in height shall have walls constructed as specified above.
Buildings three stories in height shall have the first story studs not less than two
inches by six inches (2"x6") spaced not more than sixteen inches (16”) on centers
.
Buildings two stories in height shall have walls constructed as specified above.
Buildings three stories in height shall have the first story studs not less than two
inches by six inches (2"x6") spaced not more than sixteen inches (16”) on centers
.
Page 198
Where studs do not continue full length from one story through the next story
above, a cap plate or steel member shall be provided on top of the lower story
studs or a sill plate on the upper story. Such cap plate or sill plate shall be of
sufficient ...
Where studs do not continue full length from one story through the next story
above, a cap plate or steel member shall be provided on top of the lower story
studs or a sill plate on the upper story. Such cap plate or sill plate shall be of
sufficient ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone