Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 52
Page 56
Exterior walls or parts of walls , except on street fronts , which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . Openings in exterior walls , except on street fronts , which are less than ...
Exterior walls or parts of walls , except on street fronts , which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . Openings in exterior walls , except on street fronts , which are less than ...
Page 57
The foyer shall be at the same level as the back of the auditorium and all changes in elevation between the foyer and the public street adjacent thereto shall be by ramps with a slope of not more than one in 10 .
The foyer shall be at the same level as the back of the auditorium and all changes in elevation between the foyer and the public street adjacent thereto shall be by ramps with a slope of not more than one in 10 .
Page 263
PART IX REGULATIONS FOR USE OF PUBLIC STREETS AND PROJECTIONS OVER PUBLIC PROPERTY CHAPTER 44 - PROTECTION OF ... or store any material or General equipment necessary for the work under a building permit on a street , alley or public ...
PART IX REGULATIONS FOR USE OF PUBLIC STREETS AND PROJECTIONS OVER PUBLIC PROPERTY CHAPTER 44 - PROTECTION OF ... or store any material or General equipment necessary for the work under a building permit on a street , alley or public ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone