Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 22
Page 56
... street not less than twenty feet ( 20 ' ) in width in which front shall be located the main entrance and exit of ... fronts , which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . Openings in ...
... street not less than twenty feet ( 20 ' ) in width in which front shall be located the main entrance and exit of ... fronts , which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . Openings in ...
Page 63
... street fronts which are less than five feet ( 5 ' ) from adjacent property lines , shall have no openings therein , shall be of not less than four- hour fire - resistive construction , and shall be constructed as specified in Parts V ...
... street fronts which are less than five feet ( 5 ' ) from adjacent property lines , shall have no openings therein , shall be of not less than four- hour fire - resistive construction , and shall be constructed as specified in Parts V ...
Page 65
... front directly upon at Location on least one public street , not less than twenty feet ( 20 ' ) in width , Property in which front shall be located at least one required exit . Exterior walls or parts of walls , except on street fronts ...
... front directly upon at Location on least one public street , not less than twenty feet ( 20 ' ) in width , Property in which front shall be located at least one required exit . Exterior walls or parts of walls , except on street fronts ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood