Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 61
Page 147
26 - A - ASSUMED STRENGTH OF CONCRETE MIXTURES Water - Content U. S. Gallons Per 94 - lb . Sack of Cement U.S. Gallons 742 684 6 5 Cu . Ft . 1.00 .90 .80 .67 Assumed Compressive Strength at 28 Days p . 8. 1 .
26 - A - ASSUMED STRENGTH OF CONCRETE MIXTURES Water - Content U. S. Gallons Per 94 - lb . Sack of Cement U.S. Gallons 742 684 6 5 Cu . Ft . 1.00 .90 .80 .67 Assumed Compressive Strength at 28 Days p . 8. 1 .
Page 156
The working stresses for the design of buildings or structures shall be based on the ultimate strength indicated on the drawings as specified in Section 2606 and shall be in the ratios specified in this Chapter . The ultimate strength ...
The working stresses for the design of buildings or structures shall be based on the ultimate strength indicated on the drawings as specified in Section 2606 and shall be in the ratios specified in this Chapter . The ultimate strength ...
Page 198
Such soles or plates shall be effectively anchored to the foundation and all splices and intersections shall develop the full strength of the members connected . When bearing studs or other vertical bearing members are spliced ...
Such soles or plates shall be effectively anchored to the foundation and all splices and intersections shall develop the full strength of the members connected . When bearing studs or other vertical bearing members are spliced ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone