Fire-Protection of Structural Members all girders, beams, trusses or spandrels
having rigid connections to the columns and all other members essential to the
stability thereof. The members of floor or roof panels which have no connection to
the ...
Fire-Protection of Structural Members all girders, beams, trusses or spandrels
having rigid connections to the columns and all other members essential to the
stability thereof. The members of floor or roof panels which have no connection to
the ...
Page 127
Eastern Select Structural 1100 70 Northern Hemlock & Hemlock 1 Eastern
Hemlock 700 300 1000 52 1,100,000 Hawd. Mfgrs. Assn., 900 SG Eastern
Hemlock 900 52 Oshkosh, Wis., dated 800 SG Eastern Hemlock 800 52 June 27,
1941 Oak ...
Eastern Select Structural 1100 70 Northern Hemlock & Hemlock 1 Eastern
Hemlock 700 300 1000 52 1,100,000 Hawd. Mfgrs. Assn., 900 SG Eastern
Hemlock 900 52 Oshkosh, Wis., dated 800 SG Eastern Hemlock 800 52 June 27,
1941 Oak ...
Page 185
The quality and design of steel and iron used Quality structurally in buildings or
structures shall conform to the re- and ... Design Steel used structurally shall be of
such quality as to conform to A.S.T.M. “Standard Specifications for Structural ...
The quality and design of steel and iron used Quality structurally in buildings or
structures shall conform to the re- and ... Design Steel used structurally shall be of
such quality as to conform to A.S.T.M. “Standard Specifications for Structural ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone