... structural frame and secondary members shall be designed and constructed to carry all dead , live and other loads to ... Steel or Iron Members . All struc- tural steel or iron members , not including frames or structural members for ...
... structural frame and secondary members shall be designed and constructed to carry all dead , live and other loads to ... Steel or Iron Members . All struc- tural steel or iron members , not including frames or structural members for ...
Page 94
... Structural Members Sec . 1906. Interior partitions shall be of one - hour fire - resis- tive construction or may be ... steel and Chapter 25 for solid wood . All wood columns in such structural frame shall be directly superimposed , one ...
... Structural Members Sec . 1906. Interior partitions shall be of one - hour fire - resis- tive construction or may be ... steel and Chapter 25 for solid wood . All wood columns in such structural frame shall be directly superimposed , one ...
Page 185
... Structural Steel for Bridges and Buildings , " ( A7-42 ) . Steel pipe for steel pipe columns shall be of such quality as to conform to A.S.T.M. " Standard Specifications for Welded and Seamless Steel Pipe , " ( A53-42 ) , and shall be a ...
... Structural Steel for Bridges and Buildings , " ( A7-42 ) . Steel pipe for steel pipe columns shall be of such quality as to conform to A.S.T.M. " Standard Specifications for Welded and Seamless Steel Pipe , " ( A53-42 ) , and shall be a ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood