Page 112
... tile , block , or natural stone conforming to the requirements of Section 2402 . ( c ) Use of Masonry Units . Walls ... Tile . Hollow clay tile used in exterior walls and bearing walls shall conform to the requirements for Grade " LB X ...
... tile , block , or natural stone conforming to the requirements of Section 2402 . ( c ) Use of Masonry Units . Walls ... Tile . Hollow clay tile used in exterior walls and bearing walls shall conform to the requirements for Grade " LB X ...
Page 260
... tile securely fastened with copper nails or cop- per wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 " ) , galvanized iron nails may be used , and provided further that tile with ...
... tile securely fastened with copper nails or cop- per wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 " ) , galvanized iron nails may be used , and provided further that tile with ...
Page 283
... tile , laid . Timber- Fir , dry Fir , wet Oak Water , fresh at 60 degrees Fahrenheit .. Sand , dry Sand , wet Ceilings- Lbs . Per Cu . Ft . 165 155 162 170 135 105 130 490 120 65 32 44 ... tile , Spanish .... Tile roof laid 283 Section 2301.
... tile , laid . Timber- Fir , dry Fir , wet Oak Water , fresh at 60 degrees Fahrenheit .. Sand , dry Sand , wet Ceilings- Lbs . Per Cu . Ft . 165 155 162 170 135 105 130 490 120 65 32 44 ... tile , Spanish .... Tile roof laid 283 Section 2301.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood