Page 53
... such occupancies as specified in Section 503 may be substituted in lieu
thereof. Sec. 505. The floor area of every building shall be deter- Allowable
mined by the character of the occupancy, the type of construc- Floor tion, and the
location in ...
... such occupancies as specified in Section 503 may be substituted in lieu
thereof. Sec. 505. The floor area of every building shall be deter- Allowable
mined by the character of the occupancy, the type of construc- Floor tion, and the
location in ...
Page 73
All portions of Group E occupancies customarily Light, used by human beings
shall be provided with light and ventila- Ventilation, tion by means of windows or
skylights with an area equal and to one-eighth of the total floor area or shall be ...
All portions of Group E occupancies customarily Light, used by human beings
shall be provided with light and ventila- Ventilation, tion by means of windows or
skylights with an area equal and to one-eighth of the total floor area or shall be ...
Page 159
In T-beam construc- T-Beams tion the slab and beam shall be built integrally or
otherwise effectively bonded together. The effective flange width to be used in the
design of symmetrical T-beams shall not exceed onefourth of the span length of ...
In T-beam construc- T-Beams tion the slab and beam shall be built integrally or
otherwise effectively bonded together. The effective flange width to be used in the
design of symmetrical T-beams shall not exceed onefourth of the span length of ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls feet Fire fire-resistive construction floor foot foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stage stair stairways Standard steel story street strength stress Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone