Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 72
Page 66
Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit therefor shall be fifteen square feet ( 15 sq . ft . ) . Class 3 shall be general class rooms , recreation rooms , and similar rooms and the capacity unit ...
Class 2 shall be the main exercise rooms of gymnasiums and the capacity unit therefor shall be fifteen square feet ( 15 sq . ft . ) . Class 3 shall be general class rooms , recreation rooms , and similar rooms and the capacity unit ...
Page 117
Hollow unit masonry shall be of hollow clay tile , or hollow concrete block or tile , laid up in cement mortar or cement - lime mortar , except that interior non - bearing masonry of hollow units may be laid up in gypsum mortar .
Hollow unit masonry shall be of hollow clay tile , or hollow concrete block or tile , laid up in cement mortar or cement - lime mortar , except that interior non - bearing masonry of hollow units may be laid up in gypsum mortar .
Page 128
Allowable Unit Stresses ( Cont'd . ) the species listed in Table No. 25 - A , shall not exceed the values therein given . For species and grades not given in Table No. 25 - A , the working stresses therefor shall be established by the ...
Allowable Unit Stresses ( Cont'd . ) the species listed in Table No. 25 - A , shall not exceed the values therein given . For species and grades not given in Table No. 25 - A , the working stresses therefor shall be established by the ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone