Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 87
Page 104
Retaining Foundation walls and all other walls used as retaining walls Walls in connection with Type V buildings shall be ... Exterior walls of all Type V Walls and buildings having a floor area of four hundred square feet ( 400 Wall ...
Retaining Foundation walls and all other walls used as retaining walls Walls in connection with Type V buildings shall be ... Exterior walls of all Type V Walls and buildings having a floor area of four hundred square feet ( 400 Wall ...
Page 122
Bearing Walls ( Cont'd . ) ( e ) Concentrated Loads . For calculating wall stresses , concentrated loads may be assumed to be distributed over a maximum length of wall not exceeding the center to center distance between loads nor five ...
Bearing Walls ( Cont'd . ) ( e ) Concentrated Loads . For calculating wall stresses , concentrated loads may be assumed to be distributed over a maximum length of wall not exceeding the center to center distance between loads nor five ...
Page 251
The structural requirements of the masonry and reinforced concrete walls shown in Table No. 43 - B are specified in Chapers 24 and 29 for the specific location or use of the walls and all walls shall comply with those structural ...
The structural requirements of the masonry and reinforced concrete walls shown in Table No. 43 - B are specified in Chapers 24 and 29 for the specific location or use of the walls and all walls shall comply with those structural ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
Allowable applied approved bars base beams bearing bending bolts Building Inspector carry cement cent Chapter chimneys clay coat Code column compression concrete conform connected construction covering Definition designed diameter direction distance doors Enclosure exceed exit extend exterior walls face feet Fire fire-resistive construction floor foot forms foundation four frame girders grade Group gypsum height horizontal inches iron joints joists lath least length less light load located masonry materials maximum metal occupancy one-half one-hour openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforced reinforced concrete resist rivets roof Separation shear side slab solid space span Special specified specified in Section stair stairways Standard steel story street strength stresses Strip structural studs surface Table tests thickness tile tion unit Ventilation vertical walls width wire wood Zone