Uniform Building CodePacific Coast Building Officials Conference, 1943 - Building laws |
From inside the book
Results 1-3 of 42
Page 221
... wire glass is required , it shall mean glass the thickness Wire of which at the thinnest point shall be not less than one - fourth inch ( 4 " ) and in which a wire netting is embedded . glass shall be set with putty and metal stops ...
... wire glass is required , it shall mean glass the thickness Wire of which at the thinnest point shall be not less than one - fourth inch ( 4 " ) and in which a wire netting is embedded . glass shall be set with putty and metal stops ...
Page 249
... wire or metal mesh embedded not more than three - fourths inch ( 4 " ) from the surface and securely tied into the support- ing members . Wire of not less than No. 10 B. and S. gauge wound or tied around members at not more than a six ...
... wire or metal mesh embedded not more than three - fourths inch ( 4 " ) from the surface and securely tied into the support- ing members . Wire of not less than No. 10 B. and S. gauge wound or tied around members at not more than a six ...
Page 321
... WIRE For proscenium curtain reinforcing 4102 For stucco reinforcing 4710 For tying roofing materials 4305 In fire - resistive doors Ties for fire - resistive materials WIRE GLASS In fire - resistive windows In skylights , when Required ...
... WIRE For proscenium curtain reinforcing 4102 For stucco reinforcing 4710 For tying roofing materials 4305 In fire - resistive doors Ties for fire - resistive materials WIRE GLASS In fire - resistive windows In skylights , when Required ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood