Page 94
... wood construction formed of two layers of one - inch ( 1 " ) nominal matched boards or of solid wood laminated construction not less than three and five- eighths inches ( 35 % " ) thick . Where wood partitions abut or adjoin masonry ...
... wood construction formed of two layers of one - inch ( 1 " ) nominal matched boards or of solid wood laminated construction not less than three and five- eighths inches ( 35 % " ) thick . Where wood partitions abut or adjoin masonry ...
Page 99
... wood and shall be designed and Framework erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of ...
... wood and shall be designed and Framework erected as specified in Chapter 26 for reinforced concrete , Chap- ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of ...
Page 135
... WOOD SCREWS In Pounds Per Screw Gauge of Screw Kind of Wood 12 14 16 18 20 22 24 Douglas fir Redwood Other Species 159 198 239 287 335 124 155 190 230 272 320 372 As determined by the building inspector . 400 460 TABLE NO . 25 - E ...
... WOOD SCREWS In Pounds Per Screw Gauge of Screw Kind of Wood 12 14 16 18 20 22 24 Douglas fir Redwood Other Species 159 198 239 287 335 124 155 190 230 272 320 372 As determined by the building inspector . 400 460 TABLE NO . 25 - E ...
Contents
Part IAdministrative | 33 |
Enforcement | 40 |
Part IIIRequirements Based on Occupancy | 51 |
1 other sections not shown
Other editions - View all
Common terms and phrases
allowable unit approved asbestos bars beams bending bolts Building Inspector building or structure ceiling cent chimneys clay coat Code compression compression members compressive strength conform Cont'd designed diameter doors Douglas Fir dry standpipes Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flange flat slab foot frame girders grade Group gypsum height Hollow horizontal incombustible materials joints joists least length less than one-hour live load located lumber masonry metal minimum mortar non-bearing Occupancy Separation one-half inch one-hour fire-resistive construction panel partitions permit piles pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stair stairways Standard Specifications storage strength structural steel studs tensile stress thickness tile tion total band TYPES OF CONSTRUCTION unit stress vent Ventilation Vertical Openings width wood