Page 501
EXCEPTION : Exits are not to pass through kitchens , storerooms , restrooms , closets or spaces used for similar purposes . Foyers , lobbies and reception rooms constructed as required for corridors shall not be construed as intervening ...
EXCEPTION : Exits are not to pass through kitchens , storerooms , restrooms , closets or spaces used for similar purposes . Foyers , lobbies and reception rooms constructed as required for corridors shall not be construed as intervening ...
Page 506
EXCEPTION : Stairs serving an unoccupied roof are exempt from these provisions . ( h ) Basement Stairways . Where a basement stairway and a stairway to an upper story terminate in the same exit enclosure , an approved barrier shall be ...
EXCEPTION : Stairs serving an unoccupied roof are exempt from these provisions . ( h ) Basement Stairways . Where a basement stairway and a stairway to an upper story terminate in the same exit enclosure , an approved barrier shall be ...
Page 640
EXCEPTION : A noncombustible membrane structure used exclusively as a roof and located more than 25 feet above any floor , balcony or gallery is deemed to comply with the roof construction requirements for Type 1 and Type II fire ...
EXCEPTION : A noncombustible membrane structure used exclusively as a roof and located more than 25 feet above any floor , balcony or gallery is deemed to comply with the roof construction requirements for Type 1 and Type II fire ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood