Where the occupancy separation is horizontal , structural members supporting the separation shall be protected by equivalent fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed ...
Where the occupancy separation is horizontal , structural members supporting the separation shall be protected by equivalent fire - resistive construction . ( c ) Types of Occupancy Separations . Occupancy separations shall be classed ...
Page 559
( d ) Fire - resistive Tests . The fire - protection rating of all types of required fire assemblies shall be determined in accordance with the requirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( e ) Hardware .
( d ) Fire - resistive Tests . The fire - protection rating of all types of required fire assemblies shall be determined in accordance with the requirements specified in U.B.C. Standards No. 43-2 and No. 43-4 . ( e ) Hardware .
Page 560
Except where fire tests have shown that fire dampers are not necessary to maintain the required fire resistance of the construction , fire dampers complying with the requirements of U.B.C. Standard No. 43-7 shall be installed and be ...
Except where fire tests have shown that fire dampers are not necessary to maintain the required fire resistance of the construction , fire dampers complying with the requirements of U.B.C. Standard No. 43-7 shall be installed and be ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood