Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 81
Page 45
International Conference of Building Officials. of any floor and the upper surface of the floor next above , except that the topmost story shall be that portion of a building included between the up- per surface of the topmost floor and ...
International Conference of Building Officials. of any floor and the upper surface of the floor next above , except that the topmost story shall be that portion of a building included between the up- per surface of the topmost floor and ...
Page 104
... floors in Section 2106 ( e ) . Not more than two mezzanine floors shall be in any room of a building . No mezzanine floor or floors shall cover more than 33 area of any room . Stair Construction percent of the Sec . 1805. Stairs and ...
... floors in Section 2106 ( e ) . Not more than two mezzanine floors shall be in any room of a building . No mezzanine floor or floors shall cover more than 33 area of any room . Stair Construction percent of the Sec . 1805. Stairs and ...
Page 117
... Floor Framing . Beams and girders may be of sawn timber or struc- tural glued - laminated timber and shall be not ... floor line and support floor loads , shall be not less than 8 inches in any dimension . Framed lumber or structural ...
... Floor Framing . Beams and girders may be of sawn timber or struc- tural glued - laminated timber and shall be not ... floor line and support floor loads , shall be not less than 8 inches in any dimension . Framed lumber or structural ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength