24 - C . Gypsum Masonry Sec . 2406. ( a ) General . Gypsum masonry is that form of construction made with gypsum block or tile in which the units are laid and set in gypsum mortar . Gypsum masonry shall not be used in any bearing wall ...
24 - C . Gypsum Masonry Sec . 2406. ( a ) General . Gypsum masonry is that form of construction made with gypsum block or tile in which the units are laid and set in gypsum mortar . Gypsum masonry shall not be used in any bearing wall ...
Page 563
Perlite or vermiculite gypsum plaster over self - furring metal lath wrapped directly around column , lapped l " and tied at 6 " intervals with No. 18 gauge wire . 17 14 1 % 1 18 Perlite or vermiculite gypsum plaster on metal lath ...
Perlite or vermiculite gypsum plaster over self - furring metal lath wrapped directly around column , lapped l " and tied at 6 " intervals with No. 18 gauge wire . 17 14 1 % 1 18 Perlite or vermiculite gypsum plaster on metal lath ...
Page 575
Gypsum plaster each side mixed 1 : 2 by weight , gypsum to sand aggregate . 24 Hollow ( Studless ) Gypsum Wallboard Partition Noncombusrihle Studo 292 fib No. 18 Sicel studs Spaced 16. Solid Perlite and Portland Cement 54 Perlite mixed ...
Gypsum plaster each side mixed 1 : 2 by weight , gypsum to sand aggregate . 24 Hollow ( Studless ) Gypsum Wallboard Partition Noncombusrihle Studo 292 fib No. 18 Sicel studs Spaced 16. Solid Perlite and Portland Cement 54 Perlite mixed ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood