Page 575
... Gypsum Plaster Hollow ( Studless ) Gypsum Wallboard Partition TABLE NO . 43 - B - RATED FIRE -. JJ Plaster Solid Perlite and 24 214 54 57 57 58 Set cai cips . Gypsum plaster each side mixed 1 : 2 by weight , gypsum to sand aggregate ...
... Gypsum Plaster Hollow ( Studless ) Gypsum Wallboard Partition TABLE NO . 43 - B - RATED FIRE -. JJ Plaster Solid Perlite and 24 214 54 57 57 58 Set cai cips . Gypsum plaster each side mixed 1 : 2 by weight , gypsum to sand aggregate ...
Page 579
International Conference of Building Officials. Wood Gypsum ( Continued ) TABLE NO . 43 - B - RATED FIRE -. 4 % 423 Wallboard Each Side Studs- Interior 2 " x 4 " wood studs 16 " on center with two layers % " regular gyp- sum wallboard ...
International Conference of Building Officials. Wood Gypsum ( Continued ) TABLE NO . 43 - B - RATED FIRE -. 4 % 423 Wallboard Each Side Studs- Interior 2 " x 4 " wood studs 16 " on center with two layers % " regular gyp- sum wallboard ...
Page 580
... Gypsum Wallboard Each Side 2 " x 4 " wood studs 16 " on center with two layers " Type " X " gypsum wallboard each side . Base layers applied vertically and nailed with 6d cooler nails 9 " on center . Face layer applied ver- 781 tically ...
... Gypsum Wallboard Each Side 2 " x 4 " wood studs 16 " on center with two layers " Type " X " gypsum wallboard each side . Base layers applied vertically and nailed with 6d cooler nails 9 " on center . Face layer applied ver- 781 tically ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength