Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 75
Page 31
... inspection . ( b ) Inspection Requests . It shall be the duty of the person doing the work authorized by a permit to notify the building official that such work is ready for inspection . The building official may require that every re ...
... inspection . ( b ) Inspection Requests . It shall be the duty of the person doing the work authorized by a permit to notify the building official that such work is ready for inspection . The building official may require that every re ...
Page 32
... inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or his agent wherein the same fails to comply with this code : 1. FOUNDATION INSPECTION : To be made after trenches are ...
... inspections and shall either approve that portion of the construction as completed or shall notify the permit holder or his agent wherein the same fails to comply with this code : 1. FOUNDATION INSPECTION : To be made after trenches are ...
Page 34
... inspection prior to or during installation will not be required . 6. STRUCTURAL MASONRY : During preparation of masonry wall prisms , sampling and placing of all masonry units , placement of reinforce- ment , inspection of grout space ...
... inspection prior to or during installation will not be required . 6. STRUCTURAL MASONRY : During preparation of masonry wall prisms , sampling and placing of all masonry units , placement of reinforce- ment , inspection of grout space ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength