Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 70
Page 100
... interior of the building is at least the equivalent to that required in Subsection ( b ) 1 B. 2. Foam plastic insulation having a flame - spread rating of 75 or less when tested in a thickness of 4 inches may be used in thicknesses up ...
... interior of the building is at least the equivalent to that required in Subsection ( b ) 1 B. 2. Foam plastic insulation having a flame - spread rating of 75 or less when tested in a thickness of 4 inches may be used in thicknesses up ...
Page 516
... Interior rooms may exit through adjoining or intervening rooms , provided the total distance of travel through such ... interior room and shall be connected to the school fire alarm system . EXCEPTIONS : 1. Where the aggregate occupant ...
... Interior rooms may exit through adjoining or intervening rooms , provided the total distance of travel through such ... interior room and shall be connected to the school fire alarm system . EXCEPTIONS : 1. Where the aggregate occupant ...
Page 580
... Interior Walls $ 1500 82 " 83 84. Wood Studs- Interior Partition With Gypsum Wallboard Each Side 2 " x 4 " wood studs 16 " on center with two layers " Type " X " gypsum wallboard each side . Base layers applied vertically and nailed with ...
... Interior Walls $ 1500 82 " 83 84. Wood Studs- Interior Partition With Gypsum Wallboard Each Side 2 " x 4 " wood studs 16 " on center with two layers " Type " X " gypsum wallboard each side . Base layers applied vertically and nailed with ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength