Page 52
The area of any one - or two - story building of Group B and Group H , Division 5
Occupancies shall not be limited , if the building is provided with an approved
automatic sprinkler system throughout , as specified in Chapter 38 , and entirely ...
The area of any one - or two - story building of Group B and Group H , Division 5
Occupancies shall not be limited , if the building is provided with an approved
automatic sprinkler system throughout , as specified in Chapter 38 , and entirely ...
Page 209
Flooring , including the finish floor , underlayment and subfloor , where used ,
shall meet the following requirements : Deflection under uniform design load
limited to 1 / 360 of the span between supporting joists or beams . Deflection of
flooring ...
Flooring , including the finish floor , underlayment and subfloor , where used ,
shall meet the following requirements : Deflection under uniform design load
limited to 1 / 360 of the span between supporting joists or beams . Deflection of
flooring ...
Page 663
This responsibility shall include , but need not be limited to , inspection and
approval as to the establishment of line , grade and drainage of the development
area . The civil engineer shall act as the coordinating agent in the event the need
...
This responsibility shall include , but need not be limited to , inspection and
approval as to the establishment of line , grade and drainage of the development
area . The civil engineer shall act as the coordinating agent in the event the need
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code | 18 |
Part IlDefinitions and Abbreviations | 38 |
Requirements for Group A Occupancies | 61 |
Copyright | |
Other editions - View all
Common terms and phrases
accordance allowable applied approved bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade Grain greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited live load located lumber masonry materials maximum metal nails Occupancies openings panel parallel percent permitted placed plaster plate portion pounds protection ratio reinforcement resist roof Section Select separation shear side single slab solid spaced span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood