Page 122
... Live Loads Posted . The live loads for which each floor or part thereof of a commercial or industrial building is or ... load below the allowable limits . Roof Design Sec . 2305. ( a ) General . Roofs shall sustain , within the stress ...
... Live Loads Posted . The live loads for which each floor or part thereof of a commercial or industrial building is or ... load below the allowable limits . Roof Design Sec . 2305. ( a ) General . Roofs shall sustain , within the stress ...
Page 137
... load of 10 or more per- sons , exterior exit balconies , stairways , fire escapes and similar uses . ' Residential ... ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See reviewing stands boards 1202 Footnote and ...
... load of 10 or more per- sons , exterior exit balconies , stairways , fire escapes and similar uses . ' Residential ... ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See reviewing stands boards 1202 Footnote and ...
Page 281
... loads . ' Uniform load deflection limitations : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
... loads . ' Uniform load deflection limitations : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
78 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts building official building or structure ceiling column compression compression members compressive strength concrete conform dead load diameter diaphragms exceed exit exterior walls EXTREME FIBER flange flexural footnotes Formula framing girders grade Group grout gypsum height inches on center installed joints joists least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain partitions percent permitted plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural Selected Decking shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch stairway steel strength studs Table tensile stress tension tests thickness timber tion Type U.B.C. Standard values vertical welds width wire wood yield strength