Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 86
Page 296
Concrete containing reinforcement , including prestressing steel , and designed on the assumption that the two materials act together in resisting forces . REINFORCEMENT . Material that conforms to Section 2603 ( f ) , excluding ...
Concrete containing reinforcement , including prestressing steel , and designed on the assumption that the two materials act together in resisting forces . REINFORCEMENT . Material that conforms to Section 2603 ( f ) , excluding ...
Page 484
PREPARED ROOFING is any manufactured or processed roofing material , other than untreated wood shingles and shakes , as distinguished from built - up coverings . ROOFING SQUARE is 100 square feet of roofing surface .
PREPARED ROOFING is any manufactured or processed roofing material , other than untreated wood shingles and shakes , as distinguished from built - up coverings . ROOFING SQUARE is 100 square feet of roofing surface .
Page 554
In addition to all the other requirements of this code , fireresistive materials shall meet the requirements for fire - resistive construction given in this chapter . Fire - resistive Materials Sec . 4302. ( a ) General .
In addition to all the other requirements of this code , fireresistive materials shall meet the requirements for fire - resistive construction given in this chapter . Fire - resistive Materials Sec . 4302. ( a ) General .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood