Page 195
( 1 ) Nails and Spikes . 1. Safe lateral strength . A common wire nail driven perpendicular to grain of the wood , when used to fasten wood members together , shall not be subjected to a greater load causing shear and bending than the ...
( 1 ) Nails and Spikes . 1. Safe lateral strength . A common wire nail driven perpendicular to grain of the wood , when used to fasten wood members together , shall not be subjected to a greater load causing shear and bending than the ...
Page 579
Approved metal fastener grips used with nails at vertical butt joints along studs 47 5 2 " x 4 " wood studs 16 " on center with two layers 1/2 " regular gyp572 494 444 6 791 2 " x 3 " fire - retardant.
Approved metal fastener grips used with nails at vertical butt joints along studs 47 5 2 " x 4 " wood studs 16 " on center with two layers 1/2 " regular gyp572 494 444 6 791 2 " x 3 " fire - retardant.
Page 580
Wallboard attached with 6d cement coated box nails spaced 7 " on 3 % * type plywood 1 Exterior surface with ? " drop siding or % " exterior over 12 " gypsum sheathing on 2 " x 4 " wood studs at 16 " on center ; interior surface ...
Wallboard attached with 6d cement coated box nails spaced 7 " on 3 % * type plywood 1 Exterior surface with ? " drop siding or % " exterior over 12 " gypsum sheathing on 2 " x 4 " wood studs at 16 " on center ; interior surface ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood