Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 85
Page 190
The values shall be reduced 10 percent for lumber pressure impregnated with approved fire - retardant chemicals . The values for plywood so treated shall be reduced 16 percent except for modulus of elasticity which shall be reduced 10 ...
The values shall be reduced 10 percent for lumber pressure impregnated with approved fire - retardant chemicals . The values for plywood so treated shall be reduced 16 percent except for modulus of elasticity which shall be reduced 10 ...
Page 571
10 8 One cell in wall thickness , units at least 50 percent solid , plastered each side with % " gypsum plaster . 414 11 12 Two cells in wall thickness , units at least 45 percent solid . 6 Two cells in wall thickness , units at least ...
10 8 One cell in wall thickness , units at least 50 percent solid , plastered each side with % " gypsum plaster . 414 11 12 Two cells in wall thickness , units at least 45 percent solid . 6 Two cells in wall thickness , units at least ...
Page 573
072 3972 Solid Concrete 34 Concrete Grade B cent and vertical reinforcement not less than 0.15 percent . ( Three - fourths as much for welded wire fabric . ) 3 " tile not less than 70 percent solid .
072 3972 Solid Concrete 34 Concrete Grade B cent and vertical reinforcement not less than 0.15 percent . ( Three - fourths as much for welded wire fabric . ) 3 " tile not less than 70 percent solid .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 14 |
Effective Use of the Uniform Building Code | 18 |
Definitions and Abbreviations | 38 |
Copyright | |
65 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending bolts building official ceiling Chapter column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal equipment exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces Formula frame grade greater Group gypsum height horizontal inches inspection installed joints lateral least length less limited load located masonry materials maximum metal nails Occupancies openings parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side single slab space span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood