Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 90
Page 36
... portion thereof before the same is completed , he may issue a temporary Certificate of Oc- cupancy for the use of a portion or portions of a building or structure prior to the completion of the entire building or structure . ( e ) ...
... portion thereof before the same is completed , he may issue a temporary Certificate of Oc- cupancy for the use of a portion or portions of a building or structure prior to the completion of the entire building or structure . ( e ) ...
Page 41
... portion thereof , exclusive of vent shafts and courts . The floor area of a building , or portion thereof , not provided with sur- rounding exterior walls shall be the usable area under the horizontal pro- jection of the roof or floor ...
... portion thereof , exclusive of vent shafts and courts . The floor area of a building , or portion thereof , not provided with sur- rounding exterior walls shall be the usable area under the horizontal pro- jection of the roof or floor ...
Page 498
... portion thereof shall be determined by dividing the floor area assigned to that use by the square feet per occupant as set forth in Table No. 33 - A . EXCEPTIONS : 1. The occupant load of an area having fixed seats shall be determined ...
... portion thereof shall be determined by dividing the floor area assigned to that use by the square feet per occupant as set forth in Table No. 33 - A . EXCEPTIONS : 1. The occupant load of an area having fixed seats shall be determined ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength