Uniform Building CodeInternational Conference of Building Officials, 1979 - Building laws |
From inside the book
Results 1-3 of 14
Page 4
... Sign Code . Dedicated to the development of better sign regulation . Its requirements pertain to all signs and sign construction attached to buildings . Uniform Building Code Standards . Presents in a compact and concise manner all of ...
... Sign Code . Dedicated to the development of better sign regulation . Its requirements pertain to all signs and sign construction attached to buildings . Uniform Building Code Standards . Presents in a compact and concise manner all of ...
Page 512
... signs ) when these are required for exit sign illumination . See Section 3312 ( c ) . ( b ) Exit Signs . At every required exit doorway and wherever otherwise required to clearly indicate the direction of egress , an exit sign with ...
... signs ) when these are required for exit sign illumination . See Section 3312 ( c ) . ( b ) Exit Signs . At every required exit doorway and wherever otherwise required to clearly indicate the direction of egress , an exit sign with ...
Page 560
... Signs . A sign shall be displayed permanently near or on each re- quired fire door in letters not less than 1 inch high to read as follows : Roof Coverings FIRE DOOR DO NOT OBSTRUCT Sec . 4307. Fire - retardant roof coverings shall be ...
... Signs . A sign shall be displayed permanently near or on each re- quired fire door in letters not less than 1 inch high to read as follows : Roof Coverings FIRE DOOR DO NOT OBSTRUCT Sec . 4307. Fire - retardant roof coverings shall be ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength