... Sprinkler Systems . The area specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic sprinkler system throughout . The area ...
... Sprinkler Systems . The area specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic sprinkler system throughout . The area ...
Page 94
... sprinkler systems throughout , enclosures shall not be required for escalators where the top of the escalator opening at each story is provided with a draft curtain and automatic fire sprinklers are installed around the perimeter of the ...
... sprinkler systems throughout , enclosures shall not be required for escalators where the top of the escalator opening at each story is provided with a draft curtain and automatic fire sprinklers are installed around the perimeter of the ...
Page 540
... Sprinkler Systems Sec . 3802. ( a ) General . Automatic sprinkler systems shall be provided in accordance with the provisions of this section . ( b ) Where Required . Automatic sprinkler systems shall be installed and maintained in ...
... Sprinkler Systems Sec . 3802. ( a ) General . Automatic sprinkler systems shall be provided in accordance with the provisions of this section . ( b ) Where Required . Automatic sprinkler systems shall be installed and maintained in ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength