Page 86
... square feet . The minimum net clear opening height dimension shall be 24 inches . The minimum net clear opening width dimension shall be 20 inches . Where windows are provided as a means of egress or rescue they shall have a finished ...
... square feet . The minimum net clear opening height dimension shall be 24 inches . The minimum net clear opening width dimension shall be 20 inches . Where windows are provided as a means of egress or rescue they shall have a finished ...
Page 88
... feet above the floor . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
... feet above the floor . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
Page 541
... square feet in area ; and in dressing rooms , workshops and storerooms accessory to such stages or enclosed plat ... feet in clear height used exclusively for chair or table storage and lined on the inside with materials approved for one ...
... square feet in area ; and in dressing rooms , workshops and storerooms accessory to such stages or enclosed plat ... feet in clear height used exclusively for chair or table storage and lined on the inside with materials approved for one ...
Contents
CHAPTER | 13 |
Effective Use of the Uniform Building Code | 18 |
Organization and Enforcement | 24 |
Copyright | |
72 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stress applied approved axial bars beam bending bolts building official building or structure ceiling column compression members compressive strength computed concrete conform dead load Decking diameter distance Division 1 Occupancies exceed exit exterior walls fire-resistive construction flange flexural foot Formula frame girders grade Group grout gypsum height horizontal inspection installed joints joists lath least length less live load located lumber materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear shear stress shear walls sheathing slab space space frame span specified in Section splices square feet square inch stairway steel strength studs surface Table tensile tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength