Page 6
... Allowable Location on Property Exit Facilities 805. Light , Ventilation , and Sanitation 806. Enclosure of Vertical Openings 807. Fire - extinguishing Systems 808. Special Hazards Exceptions and Deviations 40 41 41 41 42 42 42 42 43 809 ...
... Allowable Location on Property Exit Facilities 805. Light , Ventilation , and Sanitation 806. Enclosure of Vertical Openings 807. Fire - extinguishing Systems 808. Special Hazards Exceptions and Deviations 40 41 41 41 42 42 42 42 43 809 ...
Page 87
... ALLOWABLE SPAN ( Feet and Inches ) Size of Spacing of Ceiling Ceiling Joists ( Inches ) ( Inches ) Joists GROUP I ... allowable extreme fiber stress in bending of 1100 pounds per square inch . The allowable spans are based upon stress ...
... ALLOWABLE SPAN ( Feet and Inches ) Size of Spacing of Ceiling Ceiling Joists ( Inches ) ( Inches ) Joists GROUP I ... allowable extreme fiber stress in bending of 1100 pounds per square inch . The allowable spans are based upon stress ...
Page 88
International Conference of Building Officials. TABLE NO . 22 - B - ALLOWABLE SPANS FOR RAFTERS1 ( Slopes 4:12 or greater ) MAXIMUM ALLOWABLE SPAN SIZE SPACING OF OF RAFTER RAFTER ( Inches ) ( Inches ) ( Feet and Inches Measured Along ...
International Conference of Building Officials. TABLE NO . 22 - B - ALLOWABLE SPANS FOR RAFTERS1 ( Slopes 4:12 or greater ) MAXIMUM ALLOWABLE SPAN SIZE SPACING OF OF RAFTER RAFTER ( Inches ) ( Inches ) ( Feet and Inches Measured Along ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles