Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 5
Page 31
... than 60 feet 2 hour less than 20 feet Not permitted less than 5 feet 1 hour
elsewhere Protected less than 20 feet See also Section 1002 2 - Storage and
handling of Class I , II and III flammable liquids , as specified in U . B . C .
Standard No .
... than 60 feet 2 hour less than 20 feet Not permitted less than 5 feet 1 hour
elsewhere Protected less than 20 feet See also Section 1002 2 - Storage and
handling of Class I , II and III flammable liquids , as specified in U . B . C .
Standard No .
Page 45
Storage and handling of Class I , II , and III flammable liquids , as set forth in U . B
. C . Standard No . 9 - 1 - 67 ; dry cleaning plants using flammable liquids , paint
stores with bulk handling ; paint shops and spray painting rooms and shops .
Storage and handling of Class I , II , and III flammable liquids , as set forth in U . B
. C . Standard No . 9 - 1 - 67 ; dry cleaning plants using flammable liquids , paint
stores with bulk handling ; paint shops and spray painting rooms and shops .
Page 89
Any Class A or B prepared roofing . 5 . Any Class C mineral surfaced asphalt
shingles laid so that there are not less than two thicknesses at any point and the
total weight per roofing square is not less than 235 pounds . 6 . Asbestos -
cement ...
Any Class A or B prepared roofing . 5 . Any Class C mineral surfaced asphalt
shingles laid so that there are not less than two thicknesses at any point and the
total weight per roofing square is not less than 235 pounds . 6 . Asbestos -
cement ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood