Application to Existing Buildings ( Continued ) ( b ) Additions , Alterations , and
Repairs : More Than 50 Per Cent . When additions , alterations , or repairs within
any 12 - month period exceed 50 per cent of the value of an existing building or ...
Application to Existing Buildings ( Continued ) ( b ) Additions , Alterations , and
Repairs : More Than 50 Per Cent . When additions , alterations , or repairs within
any 12 - month period exceed 50 per cent of the value of an existing building or ...
Page 91
22 - 6 - Continued DESIGN LOADING AND DEFLECTION CRITERIA : Live load
— 20 pounds per square foot on the horizontal projection . Dead load weight of
roof - seven pounds per square foot on the horizontal projection - plus weight of ...
22 - 6 - Continued DESIGN LOADING AND DEFLECTION CRITERIA : Live load
— 20 pounds per square foot on the horizontal projection . Dead load weight of
roof - seven pounds per square foot on the horizontal projection - plus weight of ...
Page 119
be used gypsum sind , Concre ( Continued from Page 116 ) may be doubled
when the identical materials applied as specified Shear - resisting in this Section
are applied to both sides of the wall . Construction with Wood Frame ( b )
Masonry ...
be used gypsum sind , Concre ( Continued from Page 116 ) may be doubled
when the identical materials applied as specified Shear - resisting in this Section
are applied to both sides of the wall . Construction with Wood Frame ( b )
Masonry ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood