Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 45
Page 132
... EXCEPTION : Openings more than ten feet ( 10 ' ) above the floor of the exit court may be unprotected . Sec . 2512. ( a ) Exit Illumination . Exits shall be illuminated at any time the building is occupied with light having an intensity ...
... EXCEPTION : Openings more than ten feet ( 10 ' ) above the floor of the exit court may be unprotected . Sec . 2512. ( a ) Exit Illumination . Exits shall be illuminated at any time the building is occupied with light having an intensity ...
Page 139
... EXCEPTION : The height may be reduced to thirty - six inches ( 36 " ) for guardrails located in front of the grand- stand . A midrail shall be placed adjacent to any seat to limit the open distance above the top of any part of a seat to ...
... EXCEPTION : The height may be reduced to thirty - six inches ( 36 " ) for guardrails located in front of the grand- stand . A midrail shall be placed adjacent to any seat to limit the open distance above the top of any part of a seat to ...
Page 140
... EXCEPTION : For an open air stand with seats without backrests four exits need not be provided unless there are accommodations for more than 3000 occupants . 6. Determination of exit width . The total width of exits in feet shall be not ...
... EXCEPTION : For an open air stand with seats without backrests four exits need not be provided unless there are accommodations for more than 3000 occupants . 6. Determination of exit width . The total width of exits in feet shall be not ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles