Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 46
Page 6
... Occupancies SEC . 901 . Group D Occupancies Defined 43 902 . 903 . Construction , Height , and Area Allowable Location on Property 43 44 904 . Exit Facilities 44 905. Light , Ventilation , and Sanitation 44 906. Enclosure of Vertical ...
... Occupancies SEC . 901 . Group D Occupancies Defined 43 902 . 903 . Construction , Height , and Area Allowable Location on Property 43 44 904 . Exit Facilities 44 905. Light , Ventilation , and Sanitation 44 906. Enclosure of Vertical ...
Page 38
... OCCUPANCIES Sec . 601. Group A Occupancies shall be : ( See Table No. 5 - A ) . Sec . 602. The requirements for Group A Occupancies shall con- form to the provisions in Chapter 6 of the 1967 Edition of the Uni- form Building Code ...
... OCCUPANCIES Sec . 601. Group A Occupancies shall be : ( See Table No. 5 - A ) . Sec . 602. The requirements for Group A Occupancies shall con- form to the provisions in Chapter 6 of the 1967 Edition of the Uni- form Building Code ...
Page 132
... Occupancies . Exit illumination shall be provided with separate circuits or separate sources of power ( but not ... Occupancies and Groups B , D and H Occupancies with an occupant load of more than 50 . All other occupancies serving an ...
... Occupancies . Exit illumination shall be provided with separate circuits or separate sources of power ( but not ... Occupancies and Groups B , D and H Occupancies with an occupant load of more than 50 . All other occupancies serving an ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles