Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 64
Page 69
... Table No. 25 - A and in Groups I , II , and III set forth in Table No. 25 - I of the 1967 Edition of Volume I of the Uniform Building Code . Lumber set forth in Group IV of Table No. 25 - I may be used only under conditions specifically ...
... Table No. 25 - A and in Groups I , II , and III set forth in Table No. 25 - I of the 1967 Edition of Volume I of the Uniform Building Code . Lumber set forth in Group IV of Table No. 25 - I may be used only under conditions specifically ...
Page 116
... Table No. 24 - G for single - ply application and Table No. 24 - H for two - ply application . Vertical assemblies shall comply with Section 2403. Horizontal assemblies shall comply with Section 2404 . ( c ) Single - ply Application ...
... Table No. 24 - G for single - ply application and Table No. 24 - H for two - ply application . Vertical assemblies shall comply with Section 2403. Horizontal assemblies shall comply with Section 2404 . ( c ) Single - ply Application ...
Page 117
... Table No. 43 - B and No. 43 - C . For Shear - resisting Elements , see Table No. 24 - I . 2Nails for wood framing shall be long enough to penetrate into wood members not less than three - fourths inch ( 34 " ) and the sizes shall comply ...
... Table No. 43 - B and No. 43 - C . For Shear - resisting Elements , see Table No. 24 - I . 2Nails for wood framing shall be long enough to penetrate into wood members not less than three - fourths inch ( 34 " ) and the sizes shall comply ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood