Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 21
Page 24
... U.B.C. Standard No. 4-1-67 shall be considered incombustible within the meaning of this Section . 2. Material having a structural base of incombustible material as defined in item No. 1 above , with a surfacing material not over one ...
... U.B.C. Standard No. 4-1-67 shall be considered incombustible within the meaning of this Section . 2. Material having a structural base of incombustible material as defined in item No. 1 above , with a surfacing material not over one ...
Page 82
... U.B.C. Standard No. 29-1-67 . 4. Plastic veneer . Plastics used as veneer shall conform to the provisions of Chapter 52. When used within a building , plastic veneer shall comply with the interior finish requirements of Chap- ter 42 ...
... U.B.C. Standard No. 29-1-67 . 4. Plastic veneer . Plastics used as veneer shall conform to the provisions of Chapter 52. When used within a building , plastic veneer shall comply with the interior finish requirements of Chap- ter 42 ...
Page 84
... U.B.C. Standard No. 22-1-67 . Gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick com- plying with U.B.C. Standard No. 22-1-67 . Plywood not less than five - sixteenths inch ( " ) thick complying with U.B.C. Standard No. 25-9 ...
... U.B.C. Standard No. 22-1-67 . Gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick com- plying with U.B.C. Standard No. 22-1-67 . Plywood not less than five - sixteenths inch ( " ) thick complying with U.B.C. Standard No. 25-9 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles