Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 92
Page 4
International Conference of Building Officials. ARCH NA 140 PIZ 1967 vol 7 Preface THE UNIFORM BUILDING CODE is dedicated to the development of better building construction and greater safety to the public , by uniformity in building ...
International Conference of Building Officials. ARCH NA 140 PIZ 1967 vol 7 Preface THE UNIFORM BUILDING CODE is dedicated to the development of better building construction and greater safety to the public , by uniformity in building ...
Page 37
International Conference of Building Officials. 38 of the 1967 Edition of Volume I of the Uniform Building Code , Allowable and entirely surrounded and adjoined by public space , streets or yards not less than sixty feet ( 60 ′ ) in ...
International Conference of Building Officials. 38 of the 1967 Edition of Volume I of the Uniform Building Code , Allowable and entirely surrounded and adjoined by public space , streets or yards not less than sixty feet ( 60 ′ ) in ...
Page 40
... Uniform Building Code , Volume I. ) Sec . 707. When required by other provisions of this Code , auto- matic fire - extinguishing systems , standpipes , and basement pipe inlets shall be installed as specified in Chapter 38 of the 1967 ...
... Uniform Building Code , Volume I. ) Sec . 707. When required by other provisions of this Code , auto- matic fire - extinguishing systems , standpipes , and basement pipe inlets shall be installed as specified in Chapter 38 of the 1967 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood