Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 24
Page 6
... Ventilation , and Sanitation 806. Enclosure of Vertical Openings 807. Fire - extinguishing Systems 808. Special Hazards Exceptions and Deviations 40 41 41 41 42 42 42 42 43 809 . CHAPTER 9 . Requirements for Group D Occupancies SEC ...
... Ventilation , and Sanitation 806. Enclosure of Vertical Openings 807. Fire - extinguishing Systems 808. Special Hazards Exceptions and Deviations 40 41 41 41 42 42 42 42 43 809 . CHAPTER 9 . Requirements for Group D Occupancies SEC ...
Page 46
... Ventilation , and Sanitation A Division 4 occupancy having a floor area not exceeding twenty- five hundred square feet ( 2500 sq . ft . ) shall have exterior walls of not less than two - hour fire - resistive construction when less than ...
... Ventilation , and Sanitation A Division 4 occupancy having a floor area not exceeding twenty- five hundred square feet ( 2500 sq . ft . ) shall have exterior walls of not less than two - hour fire - resistive construction when less than ...
Page 49
... Ventilation , used by human beings shall be provided with light and ventilation and Sanitation by means of windows or skylights with an area not less than one- eighth of the total floor area one half of which shall be openable , or ...
... Ventilation , used by human beings shall be provided with light and ventilation and Sanitation by means of windows or skylights with an area not less than one- eighth of the total floor area one half of which shall be openable , or ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles