Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 22
Page 18
... additional $ 100.00 or frac- tion thereof , to and including $ 2,000.00 $ 20.00 for the first $ 2,000.00 plus $ 3.00 for each additional thousand or fraction thereof , to and including $ 25,000.00 $ 89.00 for the first $ 25,000.00 plus ...
... additional $ 100.00 or frac- tion thereof , to and including $ 2,000.00 $ 20.00 for the first $ 2,000.00 plus $ 3.00 for each additional thousand or fraction thereof , to and including $ 25,000.00 $ 89.00 for the first $ 25,000.00 plus ...
Page 49
... additional fifty square inches ( 50 sq . in . ) for each additional toilet facility ; or a mechanically operated exhaust system , which is connected to the light switch , capable of providing a complete change of air every 15 minutes ...
... additional fifty square inches ( 50 sq . in . ) for each additional toilet facility ; or a mechanically operated exhaust system , which is connected to the light switch , capable of providing a complete change of air every 15 minutes ...
Page 100
... additional flue incorporated in the chimney or for each additional forty inches ( 40 " ) in width or fraction thereof . CHAPTER 24 - LATHING , PLASTERING AND INSTALLATION OF WALLBOARD Sec . 2401. ( a ) General . The installation of lath ...
... additional flue incorporated in the chimney or for each additional forty inches ( 40 " ) in width or fraction thereof . CHAPTER 24 - LATHING , PLASTERING AND INSTALLATION OF WALLBOARD Sec . 2401. ( a ) General . The installation of lath ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles