Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 62
Page 65
... approved fire - resistive materials covered with not less than No. 26 gal- vanized sheet metal gauge with all joints in such sheet metal locklapped . All openings into any such vertical enclosure shall be protected by metal or metal ...
... approved fire - resistive materials covered with not less than No. 26 gal- vanized sheet metal gauge with all joints in such sheet metal locklapped . All openings into any such vertical enclosure shall be protected by metal or metal ...
Page 72
... approved agency , shall be nearer than six inches ( 6 " ) to any earth unless separated by concrete at least three ... approved preservative or Foundation Grade redwood , all marked or branded by an approved agency . Founda- tion Grade ...
... approved agency , shall be nearer than six inches ( 6 " ) to any earth unless separated by concrete at least three ... approved preservative or Foundation Grade redwood , all marked or branded by an approved agency . Founda- tion Grade ...
Page 81
... approved material attached to a backing for the purpose of ornamentation , protection , or insulation . Adhered Veneer is veneer secured and supported through ad- hesion to an approved bonding material applied over an approved backing ...
... approved material attached to a backing for the purpose of ornamentation , protection , or insulation . Adhered Veneer is veneer secured and supported through ad- hesion to an approved bonding material applied over an approved backing ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles