Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 10
Page 77
... backing . The distance between adjacent full - length headers shall not exceed twenty - four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four ...
... backing . The distance between adjacent full - length headers shall not exceed twenty - four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four ...
Page 81
... backing for the purpose of ornamentation , protection , or insulation . Adhered Veneer is veneer secured and supported through ad- hesion to an approved bonding material applied over an approved backing . Anchored Veneer is veneer ...
... backing for the purpose of ornamentation , protection , or insulation . Adhered Veneer is veneer secured and supported through ad- hesion to an approved bonding material applied over an approved backing . Anchored Veneer is veneer ...
Page 82
... Backing Adhered Veneer . Backing shall be continuous and may be of any material permitted by this Code . It shall have surfaces prepared to secure and support the imposed loads of veneer . Exterior veneer , including its backing , shall ...
... Backing Adhered Veneer . Backing shall be continuous and may be of any material permitted by this Code . It shall have surfaces prepared to secure and support the imposed loads of veneer . Exterior veneer , including its backing , shall ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles