Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 8
Page 24
... beam or girder placed over an open- ing in a wall , which supports the wall construction above . LIVE LOADS are all loads except dead and lateral loads . LODGING HOUSE is any building or portion thereof , contain- ing not more than five ...
... beam or girder placed over an open- ing in a wall , which supports the wall construction above . LIVE LOADS are all loads except dead and lateral loads . LODGING HOUSE is any building or portion thereof , contain- ing not more than five ...
Page 104
... Beams and Joists SIZE TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 Single Hangers Between Beams3 12 16 Double Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting ...
... Beams and Joists SIZE TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 Single Hangers Between Beams3 12 16 Double Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting ...
Page 127
... beam of white light by four per cent , or any other detection device which will work within that limitation . C - None required . D - Automatic - closing at 165 ° F . fusible link , or equal . 1For occupancy separations and protection ...
... beam of white light by four per cent , or any other detection device which will work within that limitation . C - None required . D - Automatic - closing at 165 ° F . fusible link , or equal . 1For occupancy separations and protection ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles