Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 8
Page 62
... beams , trusses , and spandrels having direct connections to the columns and all other members which are essential to the stability of the building as a whole . The members of floor or roof panels which have no connection to the columns ...
... beams , trusses , and spandrels having direct connections to the columns and all other members which are essential to the stability of the building as a whole . The members of floor or roof panels which have no connection to the columns ...
Page 69
... beams , stringers , posts , structural sheathing , and similar load - bearing members shall be of at least the minimum grades set forth in Table No. 25 - A and in Groups I , II , and III set forth in Table No. 25 - I of the 1967 Edition ...
... beams , stringers , posts , structural sheathing , and similar load - bearing members shall be of at least the minimum grades set forth in Table No. 25 - A and in Groups I , II , and III set forth in Table No. 25 - I of the 1967 Edition ...
Page 104
... Beams and Joists SIZE TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 Single Hangers Between Beams3 12 16 Double Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting ...
... Beams and Joists SIZE TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 Single Hangers Between Beams3 12 16 Double Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles